Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 89
Filtrar
1.
Dental press j. orthod. (Impr.) ; 28(1): e2321304, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO | ID: biblio-1430275

RESUMO

ABSTRACT Introduction: Titanium tetrafluoride (TiF4) is a fluoride compound that, when is applied over enamel, promotes a protection against demineralization through a titanium dioxide (TiO2) acid-resistant coat. Objectives: This study sought to verify the hypothesis that a single application of 4% TiF4 increases the resistance of enamel to dental demineralization in orthodontic patients. Materials and Methods: This controlled clinical trial followed CONSORT guidelines and investigated the prevention of enamel demineralization, fluoride retention, and the presence of a Ti layer after TiF4 application on banded teeth exposed to clinical cariogenic biofilm. Forty premolars were divided into a control group (CG; n = 20) and a test group (TG; n = 20). Teeth from both groups received prophylaxis and orthodontic bands with a cariogenic locus. In the TG, all teeth additionally underwent aqueous 4% TiF4 solution application after prophylaxis before being banded. After one month, teeth from both groups were extracted and prepared to assess the microhardness, fluoride retention, and evaluation of the Ti coating over the enamel surface. All data were analyzed with a paired Student's t-test (p<0.05). Results: Enamel microhardness and fluoride uptake were higher in TG than in CG, while the Ti layer could be seen over TG teeth that received TiF4 application. Conclusion: Under clinical circumstances, the 4% aqueous TiF4 solution was effective in preventing enamel mineral loss through increasing the enamel resistance to dental demineralization, enhancing its microhardness and fluoride uptake, and forming a Ti coat.


RESUMO Introdução: O tetrafluoreto de titânio (TiF4) é um composto fluoretado que, quando aplicado sobre o esmalte dentário, promove uma proteção contra desmineralização, por meio da formação de uma camada ácido-resistente de dióxido de titânio (TiO2). Objetivos: O presente estudo buscou verificar a hipótese de que uma única aplicação de TiF4 a 4% aumenta a resistência do esmalte dentário à desmineralização, em pacientes ortodônticos. Material e Métodos: Esse ensaio clínico controlado seguiu as diretrizes do CONSORT e investigou a prevenção da desmineralização do esmalte, retenção de flúor e a presença de uma camada de titânio após a aplicação do TiF4 em dentes bandados expostos ao biofilme cariogênico clínico. Quarenta pré-molares foram divididos em dois grupos: controle (GC; n = 20) e teste (GT; n = 20). Dentes de ambos os grupos receberam profilaxia e bandas ortodônticas com nicho cariogênico. No GT, todos os dentes também foram submetidos a aplicação de solução aquosa de TiF4 4 após profilaxia, antes de serem bandados. Após um mês, os dentes de ambos os grupos foram extraídos e preparados para avaliar a microdureza, retenção de flúor e avaliação da camada de titânio sobre a superfície do esmalte. Todos os dados foram analisados pelo teste t pareado (p<0,05). Resultados: A microdureza do esmalte e a absorção de flúor foram mais elevadas no GT do que no GC, enquanto uma camada de titânio pôde ser observada sobre os dentes do GT, que receberam aplicação TiF4. Conclusão: Em circunstâncias clínicas, a solução de TiF4 a 4% foi eficaz na prevenção da perda mineral do esmalte, por meio do aumento da resistência à desmineralização dentária, aumentando sua microdureza e absorção de flúor, e formando uma camada protetora de titânio.

2.
Dental press j. orthod. (Impr.) ; 26(3): e2119300, 2021. tab, graf
Artigo em Inglês | LILACS, BBO | ID: biblio-1286207

RESUMO

ABSTRACT Introduction: In Orthodontics and Facial Orthopedics, the timing of treatment onset may be critical and individual analysis should be applied to promote a favorable treatment planning. In this study, individual analysis of midpalatal suture (MS) and palatal measurements were performed in teenagers and young adult patients treated with rapid maxillary expansion (RME). Description: Twenty-six patients submitted to RME with a tooth-supported appliance (Hyrax) were evaluated. The inclusion criteria were: minimum age of 14 years, presenting all posterior teeth, diagnosed with transverse maxillary discrepancy, and with a clinical indication for maxillary expansion. The pretreatment CBCT scans of these patients were assessed to obtain the stages of MS maturation (MSM); density ratio (MSD); and palatal length, thickness (anterior, intermediate and posterior) and sagittal area. Results: The maturation stages present were C, D or E; the density ranged from 0.6 to 1, and lower density (MSD < 0.75) and higher density (MSD ≥ 0.75) groups were determined. Individuals with higher MSD presented smaller sagittal area, compared to the lower density group. Individuals in D and E MSM stages presented smaller sagittal area and intermediate thickness, compared to stage C. Conclusions: Smaller palatal sagittal area was observed in the high MSD groups and in the stages D and E of MSM.


RESUMO Introdução: Em Ortodontia e Ortopedia Facial, o momento de início do tratamento pode ser crítico, e uma análise individual deve ser aplicada para promover um planejamento de tratamento favorável. No presente estudo, foram realizadas a avaliação individualizada da sutura palatina mediana (SPM) e medições no palato de adolescentes e adultos jovens tratados com expansão rápida da maxila (ERM). Descrição: Foram avaliados vinte e seis pacientes submetidos à ERM com aparelho dentossuportado (Hyrax). Os critérios de inclusão foram: idade mínima de 14 anos, apresentando todos os dentes posteriores, diagnosticado com discrepância transversa da maxila e com uma indicação clínica para expansão maxilar. A tomografia computadorizada de feixe cônico (TCFC) pré-tratamento desses pacientes foi avaliada para obter os estágios de maturação da SPM (MSPM), densidade da SPM (DSPM), comprimento do palato, espessura (anterior, intermediária e posterior) e área sagital. Resultados: Os estágios de maturação presentes foram C, D ou E; a densidade variou de 0,6 a 1, e foram determinados grupos de baixa (DSPM < 0,75) e alta densidade (DSPM ≥ 0,75). Indivíduos com maior DSPM apresentaram menor área sagital, em comparação com o grupo de densidade mais baixa. Indivíduos nos estágios D e E de MSPM apresentaram menor área sagital e espessura intermediária, comparados aos indivíduos no estágio C. Conclusão: Uma menor área sagital palatina foi observada nos grupos de alta DSPM e nos estágios D e E de MSPM.


Assuntos
Humanos , Masculino , Adolescente , Adulto Jovem , Técnica de Expansão Palatina , Minorias Sexuais e de Gênero , Suturas , Homossexualidade Masculina , Suturas Cranianas/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico , Maxila/cirurgia , Maxila/diagnóstico por imagem
3.
Rev. Cient. CRO-RJ (Online) ; 4(3): 68-72, 2019.
Artigo em Inglês | BBO, LILACS | ID: biblio-1052466

RESUMO

Introduction: In the pediatric dental clinic the impacted teeth can be observedeventually, which can lead to the development of occlusion disorders. Objective:This study aimed to report a clinical case in which the surgical technique ofulectomy was used in conjunction with orthodontic treatment to aid the eruptionof a maxillary central incisor. Case Report: Male patient, 13 years old, Angle ClassI in the mixed dentition stage, with the tooth 21 impacted and reduced space forits eruption due to the migration of adjacent teeth. Fixed appliance was mountedwith Edgewise brackets using 0.20" stainless steel archwire with tight omega andactive spring between teeth 11 and 22 to recover the space of 21, but the passiveeruption was not observed. A fibrous gingival tissue was found, which by palpationrevealed the incisal edge of the tooth 21. The patient was referred to a pediatricdental clinic for a ulectomy. The minimally invasive surgical procedure consistedof the excision of the gingival tissue that covered the crown of the tooth 21 allowingits eruption in the dental arch. After the surgery, the teeth erupted and correctiveorthodontic treatment continued. Conclusion: The ulectomy technique associatedwith orthodontic treatment allowed to reestablish conditions for the developmentof dentition with satisfactory aesthetic and functional characteristics.


Introdução: Eventualmente na clínica odontológica, pode ser observada aimpacção de dentes, que pode acarretar transtornos para o desenvolvimento daoclusão. Objetivo: Objetivou-se relatar um caso clínico no qual a técnica cirúrgicade ulectomia foi utilizada, associada ao tratamento ortodôntico para auxiliar aerupção dentária de um incisivo central superior. Relato de Caso: Paciente dosexo masculino, 13 anos de idade, Classe I de Angle na fase de dentição mista, comdente 21 incluso e espaço reduzido para sua erupção em função da migração dosdentes adjacentes. Foi montado aparelho fixo com bráquetes prescrição Edgewise,utilizando arco 0,20" aço inoxidável com ômega justo e mola ativa entre osdentes 11 e 22 para recuperação do espaço do 21, mas não observou-se a erupçãopassiva. Constatou-se presença de tecido gengival fibroso que, ao toque,evidenciava a borda incisal do referido dente. O paciente foi encaminhado paraclínica de Odontopediatria para a realização da ulectomia. O procedimentocirúrgico minimamente invasivo, consistiu na exérese do tecido gengival querevestia a coroa do dente 21 não irrompido, permitindo sua erupção no arcodentário. Após a cirurgia, o dente irrompeu e o tratamento ortodôntico corretivoprosseguiu. Conclusão: A técnica da ulectomia associada ao tratamentoortodôntico permitiu restabelecer condições para desenvolvimento da dentiçãocom características estético-funcionais satisfatórias.


Assuntos
Odontopediatria , Ortodontia , Erupção Dentária , Dente Impactado , Dentição Mista , Incisivo , Má Oclusão Classe I de Angle
4.
Dental press j. orthod. (Impr.) ; 22(4): 113-117, July-Aug. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-891081

RESUMO

ABSTRACT The sustainability of the natural resources of our planet is a topic for worldwide debate. Mankind, during its evolution as a species, has not been greatly concerned about conserving the environment in which we live. Nowadays we are reaping the fruits of this neglect. Climatic changes and storms are good examples of this. We, humans, must re-think our attitudes in order to leave the planet in a healthy state to be used by our descendants. But thinking of orthodontics, what can we do as orthodontists? From this perspective, the authors of the present study aimed, in a clear and objective manner, to present simple and sustainable ways to proceed during our activity as orthodontists, in order to minimize the effects on nature, caused by man.


RESUMO A sustentabilidade dos recursos naturais de nosso planeta é tema de debate em todo o mundo. O homem, durante a evolução como espécie, pouco se preocupou em conservar o meio ambiente em que vive. Nos dias de hoje, colhemos os frutos do descaso; mudanças climáticas e tempestades são bons exemplos disso. Nós, seres humanos, devemos repensar nossas atitudes, a fim de deixar o planeta propício para que nossos descendentes possam utilizá-lo. Mas, pensando-se na Ortodontia, o que nós ortodontistas podemos fazer? Nessa perspectiva, os autores do presente estudo se propuseram a apresentar, de forma clara e objetiva, formas simples e sustentáveis para serem utilizadas durante nossa atividade como ortodontistas, a fim de minimizar os efeitos causados pelo homem na natureza.


Assuntos
Ortodontia/normas , Conservação dos Recursos Naturais
5.
Ortho Sci., Orthod. sci. pract ; 10(39): 363-375, 2017. ilus
Artigo em Português | LILACS, BBO | ID: biblio-868296

RESUMO

Os pré-molares são os dentes comumente extraídos com finalidade ortodôntica, e por isso, a extração de outros dentes é denominada como atípica ou não convencional. O objetivo deste artigo é apresentar uma revisão da literatura sobre tratamentos ortodônticos com essas extrações, analisando o diagnóstico e tratamento, com ênfase nas indicações e limitações. Foram discutidos e apresentados pontos relevantes das extrações de incisivos inferiores, molares, caninos e incisivos superiores. Apesar de pouco frequentes, as extrações atípicas são uma alternativa válida para correção de maloclusões. Quando bem indicados e realizados, são tratamentos que podem simplificar a mecânica ortodôntica, reduzir o tempo de tratamento e oferecer menor custo biológico comparado a outras alternativas. Entretanto, concluiu-se que os casos de extrações atípicas apresentam indicações específicas e restritas, não sendo possível estabelecer protocolos de tratamento e cada caso deve ser cuidadosamente planejado.(AU)


The premolars are commonly extracted for orthodontic purposes, and therefore the extraction of any other teeth is denominated as atypical or non-conventional. The objective of this article is to present a literature review of orthodontic treatments with atypical extractions, analyzing diagnosis and treatment and emphasizing indications and limitations. Relevant aspects regarding extractions of lower incisors, molars, canines and upper incisors were discussed. Although being uncommon, atypical extractions are a valid alternative for correcting malocclusions. When well indicated and performed, they can simplify orthodontic mechanics, reduce treatment time, and offer lower biological cost compared to other alternatives. Nevertheless, it may be concluded that cases of atypical extractions present specific and restricted indications and it is not possible to establish treatment protocols as each case must be planned carefully.(AU)


Assuntos
Ortodontia , Ortodontia Corretiva , Extração Dentária
6.
Dental press j. orthod. (Impr.) ; 20(5): 35-42, tab, graf
Artigo em Inglês | LILACS | ID: lil-764538

RESUMO

Objective: To compare in vivo orthodontic mini-implants (MI) of smooth (machined) and rough (acid etched) surfaces, assessing primary and secondary stability.Methods:Thirty-six (36) MI were inserted in the mandibles of six (6) dogs. Each animal received six (6) MI. In the right hemiarch, three (3) MI without surface treatment (smooth) were inserted, whereas in the left hemiarch, another three (3) MI with acid etched surfaces (rough) were inserted. The two distal MI in each hemiarch received an immediate load of 1.0 N for 16 weeks, whereas the MI in the mesial extremity was not subject to loading. Stability was measured by insertion and removal torque, initial and final mobility and by inter mini-implant distance.Results:There was no statistical behavioral difference between smooth and rough MI. High insertion torque and reduced initial mobility were observed in all groups, as well as a reduction in removal torques in comparison with insertion torque. Rough MI presented higher removal torque and lower final mobility in comparison to smooth MI. MI did not remain static, with displacement of rough MI being smaller in comparison with smooth MI, but with no statistical difference.Conclusions:MI primary stability was greater than stability measured at removal. There was no difference in stability between smooth and rough MI when assessing mobility, displacement and insertion as well as removal torques.


Objetivo: comparar, in vivo, mini-implantes (MI) com superfície lisa (usinada) e porosa (tratada com ácido), avaliando sua estabilidade primária e secundária.Métodos:trinta e seis MI foram inseridos na mandíbula de seis cães, e cada animal recebeu seis MI. Na hemiarcada direita, foram inseridos três MI sem tratamento da superfície (liso); na esquerda, outros três com a superfície tratada com ácido (poroso). Os dois MI distais de cada hemiarcada receberam carga imediata de 1,0N durante dezesseis semanas, e o MI da extremidade mesial não recebeu carregamento. A estabilidade foi medida pelos torques de inserção e de remoção, pela mobilidade inicial e final, e pela distância inter-MI.Resultados:não houve diferença estatística do comportamento entre os MI lisos e porosos. No entanto, observou-se torque de inserção elevado e mobilidade inicial reduzida em todos os grupos. Para todos os grupos, houve redução dos torques de remoção, em relação ao de inserção. Os MI porosos apresentaram maior torque de remoção e menor mobilidade final, em relação aos MI lisos. Os MI não permaneceram estáticos, sendo o deslocamento dos MI porosos menor em relação aos MI lisos, mas sem diferença estatística.Conclusões:a estabilidade primária dos MI foi maior do que a estabilidade medida na sua remoção; não houve diferença na estabilidade entre os MI lisos e porosos ao avaliar-se a mobilidade, o deslocamento e os torques de inserção e remoção.


Assuntos
Animais , Masculino , Cães , Propriedades de Superfície , Osseointegração , Implantes Dentários para Um Único Dente , Implantação Dentária Endóssea/instrumentação , Titânio , Falha de Restauração Dentária/estatística & dados numéricos , Torque , Implantação Dentária Endóssea/métodos , Análise do Estresse Dentário/métodos , Procedimentos de Ancoragem Ortodôntica/instrumentação , Procedimentos de Ancoragem Ortodôntica/métodos , Carga Imediata em Implante Dentário/instrumentação , Metalurgia/métodos
7.
Dental press j. orthod. (Impr.) ; 20(2): 29-34, Mar-Apr/2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-745854

RESUMO

OBJECTIVE: The purpose of this study was to assess the influence of magnification and superimposition of structures on CBCT-generated lateral cephalometric radiographs (LCR) using different segments of the cranium. METHODS: CBCT scans of 10 patients were selected. Four LCR were generated using Dolphin Imaging(r) software: full-face, right side, left side and center of the head. A total of 40 images were imported into Radiocef Studio 2(r), and the angles of the most common cephalometric analyses were traced by the same observer twice and within a 10-day interval. Statistical analyses included intraexaminer agreement and comparison between methods by means of intraclass correlation coefficient (ICC) and Bland-Altman agreement tests. RESULTS: Intraexaminer agreement of the angles assessed by ICC was excellent (> 0.90) for 83% of measurements, good (between 0.75 and 0.90) for 15%, and moderate (between 0.50 and 0.75) for 2% of measurements. The comparison between methods by ICC was excellent for 68% of measurements, good for 26%, and moderate for 6%. Variables presenting wider confidence intervals (> 6o) in the Bland-Altman tests, in intraexaminer assessment, were: mandibular incisor angle, maxillary incisor angle, and occlusal plane angle. And in comparison methods the variables with wider confidence interval were: mandibular incisor, maxillary incisor, GoGn, occlusal plane angle, Frankfort horizontal plane (FHP), and CoA. CONCLUSION: Superimposition of structures seemed to influence the results more than magnification, and neither one of them significantly influenced the measurements. Considerable individual variability may occur, especially for mandibular and maxillary incisors, FHP and occlusal plane. .


OBJETIVO: o objetivo do presente estudo foi avaliar a influência da sobreposição estrutural e da magnificação nas radiografias cefalométricas laterais (RCL) geradas por meio de tomografias computadorizadas de feixe cônico (TCFC), usando diferentes segmentos do crânio. MÉTODOS: foram selecionadas 10 tomografias de pacientes. Quatro RCL foram geradas usando Dolphin Imaging, sendo face total, lado direito, lado esquerdo e o centro da cabeça. Um total de 40 imagens foi importado para o Radiocef Studio, e os ângulos das análises cefalométricas mais comuns foram medidos pelo mesmo observador, duas vezes, em um intervalo de 10 dias. As análises estatísticas incluíram concordância intraexaminador e comparação entre os métodos por meio do coeficiente de correlação intraclasse (ICC) e testes de concordância de Bland-Altman. RESULTADOS: a concordância intraexaminador dos ângulos avaliados pelo ICC foi excelente (> 0,90) para 83% das medições, boa (entre 0,75 e 0,90) para 15%, e moderada (entre 0,50 e 0,75) para 2% das medições. A comparação entre os métodos por ICC foi excelente para 68% das medições, boa para 26% e moderada para 6%. As variáveis que apresentaram intervalos de confiança mais amplos (> 6°) nos testes de Bland-Altman, na avaliação intraexaminador, foram: incisivo superior, incisivo inferior e plano oclusal, enquanto nos métodos de comparação, as variáveis com intervalos de confiança mais amplos foram: incisivo inferior, incisivo superior, GoGn, ângulo do plano oclusal, plano horizontal de Frankfort e CoA. CONCLUSÃO: a sobreposição estrutural pareceu influenciar os resultados mais do que a magnificação, mas os métodos não influenciaram significativamente as medições. Considerável variabilidade individual pode ocorrer especialmente para os incisivos superiores e inferiores, plano horizontal de Frankfort e plano oclusal. .


Assuntos
Reparo do DNA , Desoxiguanosina/análogos & derivados , Proteínas de Escherichia coli/genética , Escherichia coli/genética , Regulação Bacteriana da Expressão Gênica , Mutagênese/efeitos da radiação , Açúcares Ácidos/metabolismo , Bioensaio , Quebras de DNA de Cadeia Dupla , DNA Polimerase beta/genética , DNA Polimerase beta/metabolismo , Desoxiguanosina/química , Desoxiguanosina/metabolismo , Proteínas de Escherichia coli/metabolismo , Escherichia coli/metabolismo , Escherichia coli/efeitos da radiação , Endonucleases Flap/genética , Endonucleases Flap/metabolismo , Furanos/química , Furanos/metabolismo , Raios gama , Mutação , Plasmídeos , Açúcares Ácidos/química
9.
Braz. oral res. (Online) ; 29(1): 1-7, 2015. tab, ilus
Artigo em Inglês | LILACS | ID: lil-777194

RESUMO

The objective of this study was to assess the influence of cortical thickness and bone density on the insertion torque of a mini-implant (MI) with microthreads. Mini-implants with lengths of 6 and 8 mm in the active part were inserted into synthetic bone blocks (polyurethane resin). The density of these blocks was 20 pounds per cubic foot (pcf), simulating bone marrow, and that of blocks 1, 2, and 3-mm-thick blocks was 40 pcf, simulating cortical bone. Blocks with uniform density of 40 pcf were also used to simulate bone areas of greater density. Insertion torque was quantified with a universal testing machine (EMIC). For both MIs, increasing insertion torque was associated with increasing cortical bone thickness. For the same MI length, significant differences were observed among all assessed groups. The insertion torque of the 6-mm-long MI inserted in a 3-mm-thick cortical bone was equivalent to that of the 8-mm-long MI inserted in a 1-mm-thick cortical bone. MIs inserted in bone blocks of greater density presented insertion torque values almost twice as high as those in other groups. The shorter MI, the lower the insertion torque, and the greater the cortical bone thickness, the greater the insertion torque. To minimize fracture risk, the size of MI should be selected according to the insertion site.


Assuntos
Humanos , Implantes Dentários , Procedimentos de Ancoragem Ortodôntica/métodos , Torque , Análise de Variância , Densidade Óssea , Osso e Ossos/anatomia & histologia , Análise do Estresse Dentário , Análise de Falha de Equipamento , Teste de Materiais , Desenho de Aparelho Ortodôntico , Procedimentos de Ancoragem Ortodôntica/instrumentação , Valores de Referência , Fatores de Risco , Estatísticas não Paramétricas , Propriedades de Superfície
10.
Dental press j. orthod. (Impr.) ; 19(3): 90-94, May-Jun/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-723144

RESUMO

OBJECTIVE: This study aimed to measure insertion torque, tip mechanical resistance to fracture and transmucosal neck of mini-implants (MI) (Conexão Sistemas de PróteseT), as well as to analyze surface morphology. METHODS: Mechanical tests were carried out to measure the insertion torque of MIs in different cortical thicknesses, and tip mechanical resistance to fracture as well as transmucosal neck of MIs. Surface morphology was assessed by scanning electron microscopy (SEM) before and after the mechanical tests. RESULTS: Values of mechanical resistance to fracture (22.14 N.cm and 54.95 N.cm) were higher and statistically different (P < 0.05) from values of insertion torque for 1-mm (7.60 N.cm) and 2-mm (13.27 N.cm) cortical thicknesses. Insertion torque was statistically similar (P > 0.05) to torsional fracture in the tip of MI (22.14 N.cm) when 3 mm cortical thickness (16.11 N.cm) and dense bone (23.95 N.cm) were used. Torsional fracture of the transmucosal neck (54.95 N.cm) was higher and statistically different (P < 0.05) from insertion torsional strength in all tested situations. SEM analysis showed that the MIs had the same smooth surface when received from the manufacturer and after the mechanical tests were performed. Additionally, no significant marks resulting from the manufacturing process were observed. CONCLUSION: All mini-implants tested presented adequate surface morphology. The resistance of mini-implants to fracture safely allows placement in 1 and 2-mm cortical thickness. However, in 3-mm cortical thickness and dense bones, pre-drilling with a bur is recommended before insertion. .


OBJETIVOS: os objetivos foram determinar os torques de inserção, a resistência mecânica à fratura da ponta e do perfil transmucoso de mini-implantes (MI) de uma marca comercial (Conexão Sistemas de Prótese), e analisar sua morfologia de superfície. MÉTODOS: foram realizados testes mecânicos para medir o torque de inserção dos MI em corticais de diferentes espessuras, também foi avaliada a resistência à fratura da ponta e do perfil transmucoso. Antes e após os ensaios mecânicos, foi avaliada a superfície dos MI no microscópio eletrônico de varredura (MEV). RESULTADOS: os valores de resistência à fratura dos MI (22,14N.cm2 e 54,95N.cm2) foram maiores e estatisticamente diferentes (p < 0,05) dos torques de inserção nas corticais de 1mm (7,60N.cm2) e de 2mm (13,27N.cm2). Entretanto, o valor do torque de inserção na cortical de 3mm (16,11N.cm2) e no osso denso (23,95N.cm2) foi estatisticamente semelhante (p > 0,05) ao torque de fratura da ponta do MI (22,14N.cm2). O torque de fratura do perfil transmucoso (54,95N.cm2) foi maior e estatisticamente diferente (p < 0,05) dos torques de inserção em qualquer uma das situações testadas. A análise em MEV mostrou que os MI, como recebidos e após os testes mecânicos, possuem superfícies lisas e sem marcas significativas oriundas do processo de fabricação. CONCLUSÃO: os MI avaliados apresentaram adequada morfologia da superfície. A resistência do MI foi compatível com a instalação em corticais de 1 e 2mm, porém, em cortical de 3mm e em ossos densos recomenda-se prévia perfuração com broca. .


Assuntos
Humanos , Osso e Ossos/cirurgia , Implantes Dentários , Procedimentos de Ancoragem Ortodôntica/instrumentação , Fenômenos Biomecânicos , Densidade Óssea/fisiologia , Falha de Equipamento , Teste de Materiais , Microscopia Eletrônica de Varredura , Miniaturização , Desenho de Aparelho Ortodôntico , Estresse Mecânico , Propriedades de Superfície , Torque , Torção Mecânica
11.
Dental press j. orthod. (Impr.) ; 19(2): 108-114, Mar-Apr/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-714614

RESUMO

Objective: To test the null hypothesis that the aging process in self-ligating brackets is not higher than in conventional brackets. Methods: Twenty-five conventional (GN-3M/Unitek; GE-GAC; VE-Aditek) and 25 self-ligating (SCs-3M/Unitek; INs-GAC; ECs-Aditek) metal brackets from three manufacturers (n = 150) were submitted to aging process in 0.9% NaCl solution at a constant temperature of 37 ± 1ºC for 21 days. The content of nickel, chromium and iron ions in the solution collected at intervals of 7, 14 and 21 days was quantified by atomic absorption spectrophotometry. After the aging process, the brackets were analyzed by scanning electron microscopy (SEM) under 22X and 1,000X magnifications. Results: Comparison of metal release in self-ligating and conventional brackets from the same manufacturer proved that the SCs group released more nickel (p < 0.05) than the GN group after 7 and 14 days, but less chromium (p < 0.05) after 14 days and less iron (p < 0.05) at the three experimental time intervals. The INs group released less iron (p < 0.05) than the GE group after 7 days and less nickel, chromium and iron (p < 0.05) after 14 and 21 days. The ECs group released more nickel, chromium and iron (p < 0.05) than the VE group after 14 days, but released less nickel and chromium (p < 0.05) after 7 days and less chromium and iron (p < 0.05) after 21 days. The SEM analysis revealed alterations on surface topography of conventional and self-ligating brackets. Conclusions: The aging process in self-ligating brackets was not greater than in conventional brackets from the same manufacturer. The null hypothesis was accepted. .


Objetivo: testar a hipótese nula de que o processo de envelhecimento em braquetes autoligáveis não é superior ao de braquetes convencionais. Métodos: Vinte e cinco braquetes metálicos convencionais (GN, 3M/Unitek; GE, GAC; VE, Aditek) e 25 autoligáveis (SCs, 3M/Unitek; INs, GAC; ECs, Aditek) de três fabricantes (n = 150) foram submetidos ao envelhecimento em solução de NaCl à temperatura constante de 37 ± 1ºC, durante 21 dias. O conteúdo de íons níquel, cromo e ferro na solução coletada com 7, 14 e 21 dias foi quantificado por meio de espectrofotometria de absorção atômica. Depois de completado o processo de envelhecimento, os braquetes foram analisados com microscópio eletrônico de varredura (MEV), em magnificações de 22x e de 1.000x. Resultados: comparando-se a liberação de metais por braquetes autoligáveis e convencionais do mesmo fabricante, observou-se que o grupo SCs liberou mais níquel (p < 0,05) que o grupo GN após 7 e 14 dias, mas menos cromo (p < 0,05) após 14 dias e menos ferro (p < 0,05) nos três períodos experimentais. O grupo INs liberou menos ferro (p < 0,05) que o grupo GE após 7 dias, e menos níquel, cromo e ferro (p < 0,05) após 14 e 21 dias. O grupo ECs liberou mais níquel, cromo e ferro (p < 0,05) que o grupo VE após 14 dias; entretanto, liberou menos níquel e cromo (p < 0,05) após 7 dias e menos cromo e ferro (p < 0,05) após 21 dias. A análise no MEV demonstrou alterações na topografia da superfície de braquetes convencionais e autoligáveis. Conclusões: o processo de envelhecimento em braquetes autoligáveis não foi superior ao de braquetes convencionais do mesmo fabricante. A hipótese nula está aceita. .


Assuntos
Humanos , Ligas Dentárias/química , Desenho de Aparelho Ortodôntico , Braquetes Ortodônticos , Corrosão , Cromo/química , Difusão , Ferro/química , Teste de Materiais , Microscopia Eletrônica de Varredura , Níquel/química , Espectrofotometria Atômica , Propriedades de Superfície , Cloreto de Sódio/química , Aço Inoxidável/química , Temperatura , Fatores de Tempo
12.
Dental press j. orthod. (Impr.) ; 19(2): 90-95, Mar-Apr/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-714616

RESUMO

Objective: The aim of this study was to validate a method used to assess dental asymmetry, in relation to the skeletal midline, by means of CBCT. Methods: Ten patients who had CBCT scans taken were randomly selected for this study. Five different observers repeated 10 landmarks (x, y and z variables for each) and 12 linear measurements within 10 days. Measurements were taken in both arches to evaluate symmetry of first molars, canines and dental midline in relation to the skeletal midline. Intraclass correlation coefficient (ICC) was carried out to assess intra- and interobserver reliability for landmarks and distances. Average mean difference was also assessed to check measurement errors between observers. Results: ICC landmarks was ≥ 0.9 for 27 (90%) and 25 (83%) variables for intra- and interobserver, respectively. ICC for distances was ≥ 0.9 for 7 (58%) and 5 (42%), respectively. All ICC landmarks for distances were >0.75 for both intra- and interobserver. The mean difference between observers was ≤ 0.6 mm for all the distances. Conclusion: The method used to assess dental asymmetry by means of CBCT is valid. Measurements of molars, canines and dental midline symmetry with the skeletal midline are reproducible and reliable when taken by means of CBCT and by different operators. .


Objetivo: validar um método para avaliar assimetria dentária, em relação à linha média esquelética, usando TCFC. Métodos: dez pacientes que realizaram TCFC foram selecionados aleatoriamente para esse estudo. Cinco diferentes observadores repetiram 10 pontos de referência (com variáveis x, y e z, para cada ponto) e 12 medidas lineares em um intervalo de 10 dias. As medições foram realizadas em ambas as arcadas, para avaliar a simetria de primeiros molares, caninos e linha média dentária, em relação à linha média esquelética. Índice de correlação intraclasse (ICC) foi realizado para verificar a confiabilidade intraobservador e interobservadores para os pontos de referência e distâncias. A diferença média também foi avaliada, para checar os erros de mensuração entre os observadores. Resultados: ICC para os pontos de referência foram ≥ 0,9 para 27 (90%) e 25 (83%) das variáveis para intra- e interobservadores respectivamente. ICC para distâncias foi ≥ 0,9 para 7 (58%) e 5 (42%), respectivamente. Todas as medidas de ICC para distâncias foram > 0,75 para intraobservador e interobservadores. A diferença média entre observadores foi ≤ 0,6mm para todas as distâncias. Conclusão: o método de verificação de assimetria dentária utilizando TCFC é válido. Medições de molares, caninos e linha média dentária com a linha média esquelética são reproduzíveis e confiáveis quando feitas utilizando TCFC, mesmo que por diferentes operadores. .


Assuntos
Humanos , Cefalometria/estatística & dados numéricos , Tomografia Computadorizada de Feixe Cônico/estatística & dados numéricos , Má Oclusão , Coroa do Dente , Pontos de Referência Anatômicos , Dente Canino , Arco Dental , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Incisivo , Mandíbula , Maxila , Dente Molar , Osso Nasal , Variações Dependentes do Observador , Reprodutibilidade dos Testes
13.
Dental press j. orthod. (Impr.) ; 18(6): 45-50, Nov.-Dec. 2013. ilus, tab
Artigo em Inglês | LILACS | ID: lil-697730

RESUMO

OBJECTIVE: The aim of the present study was to assess the influence of saliva contamination over the structural strength and integrity of conventional glass-ionomer cements used for cementing orthodontic bands in the absence and presence of a surface-protecting varnish. METHOD: 48 samples were prepared by inserting 3 types of glass-ionomer cements into standardized metallic matrixes of 10 mm of diameter and 2 mm of depth. The cements used were: Meron (VOCO), Ketac-Cem (3M ESPE) and Vidrion C (DFL), all of which comprised groups A, B and C, respectively. Subgroups A1, B1 and C1 comprised samples with no surface protection, whereas subgroups A2, B2 and C2 comprised samples of which surface was coated with Cavitine varnish (SS White), after cement manipulation and application, in order to protect the cement applied. All samples were stored in artificial saliva for 24 hours at 37ºC. A Vickers diamond micro-durometer was used to produce indentations on the non-treated group (non-varnished) and the treated group (varnished). RESULTS: Varnished materials had significantly higher microhardness values in comparison to non-varnished materials. Ketac-Cem had the highest microhardness value among the varnished materials. CONCLUSION: Varnish application is necessary to preserve the cement and avoid enamel decalcification. Glass-ionomer cements should be protected in order to fully keep their properties, thus, contributing to dental health during orthodontic treatment.


OBJETIVO: avaliar a influência da contaminação salivar na resistência estrutural e integridade de cimentos de ionômero de vidro convencionais utilizados para cimentação de bandas ortodônticas na ausência e na presença de um verniz protetor de superfície. MÉTODOS: quarenta e oito corpos de prova foram confeccionados a partir de três cimentos ortodônticos, com auxílio de matrizes metálicas padronizadas com 10mm de diâmetro e 2mm de altura. Os cimentos utilizados foram: Meron (Voco), Ketac-Cem (3M ESPE) e Vidrion C (DFL), compondo os grupos A, B e C, respectivamente. Metade dessas amostras não recebeu nenhum tipo de proteção superficial, constituindo os subgrupos A1, B1 e C1, enquanto, os subgrupos A2, B2 e C2 tiveram suas superfícies isoladas com verniz Cavitine (SS White) após manipulação e aplicação do cimento, com intuito de proteger a superfície do cimento. As amostras foram armazenadas em saliva artificial por 24 horas a 37ºC. Foi realizado um ensaio de microdureza (Vickers) para avaliação da dureza de superfície do grupo não-tratado (sem isolamento) e do grupo tratado (agente protetor). RESULTADOS: os materiais previamente isolados com o verniz obtiveram valores de microdureza significativamente maiores que os não-isolados. O cimento Ketac-Cem apresentou, estatisticamente, a maior microdureza entre os materiais protegidos. CONCLUSÃO: o isolamento com verniz mostrou-se necessário para preservação do cimento e, consequentemente, de sua capacidade de evitar possíveis desmineralizações dentárias. Os cimentos de ionômero de vidro devem ser protegidos para manutenção de sua integridade, contribuindo para saúde dental durante o tratamento ortodôntico.


Assuntos
Humanos , Cimentos de Ionômeros de Vidro/química , Braquetes Ortodônticos , Substâncias Protetoras/química , Diamante/química , Contaminação de Equipamentos , Dureza , Teste de Materiais , Óxido de Magnésio/química , Cimento de Policarboxilato/química , Estresse Mecânico , Propriedades de Superfície , Saliva Artificial/química , Temperatura , Fatores de Tempo , Óxido de Zinco/química
14.
Dental press j. orthod. (Impr.) ; 18(4): 98-103, July-Aug. 2013. ilus, tab
Artigo em Inglês | LILACS | ID: lil-695125

RESUMO

INTRODUCTION: Orthodontic patients frequently present composite resin restorations, however there are few studies that evaluate the best way for orthodontic bonding in this situation. OBJECTIVE: The objective of this work was to evaluate the bond strength of orthodontic brackets in resin restorations with surface treatment. METHODS: Fifty one bovine lower incisors were randomly divided into three groups. On the control group (CG) the brackets were bonded to dental enamel; on experimental groups, brackets were bonded to resin restoration with diamond drill treatment (EGT) and with no treatment (EGN). The teeth were placed in PVC tubes with autopolymerized acrylic resin. The shear test was performed in EMIC universal testing machine. The groups were submitted to ANOVA analysis of variance with Tukey post test to verify the statistical difference between groups (α = 0.05). RESULTS: CG (6.62 MPa) and EGT (6.82 MPa) groups presented similar results, while EGN (5.07 MPa) obtained statistically lower results (p < 0.05). CONCLUSION: Therefore, it is concluded that the best technique for bonding of orthodontic brackets on composite resin restorations is the performance of surface detritions.


INTRODUÇÃO: frequentemente, os pacientes ortodônticos apresentam restaurações de resina composta; no entanto, existem poucos estudos que avaliam a melhor forma de colagem ortodôntica nessa situação. OBJETIVO: o objetivo do presente trabalho foi avaliar a força adesiva de braquetes ortodônticos em restaurações resinosas com tratamento de superfície. MÉTODOS: foram utilizados 51 incisivos inferiores bovinos divididos aleatoriamente em três grupos. No grupo controle (GC), os braquetes foram colados em esmalte dentário; nos grupos experimentais com tratamento (GCT) e sem tratamento (GST), os braquetes foram colados em restauração de resina previamente realizada, diferenciando-se pelo tratamento de superfície com broca diamantada. Os dentes foram incluídos em tubos de PVC com resina acrílica autopolimerizável. O ensaio de cisalhamento foi executado em máquina universal de ensaios Emic. Os grupos foram submetidos à ANOVA com pós-teste de Tukey para verificação da diferença estatística entre os grupos (α = 0,05). RESULTADOS: GC (6,62MPa) e GCT (6,82MPa) apresentaram resultados semelhantes, enquanto o GST (5,07MPa) obteve resultados estatisticamente menores (p < 0,05). CONCLUSÃO: conclui-se que a melhor técnica de colagem de braquetes ortodônticos em restaurações de resina composta é a de realização de desgaste sobre a superfície.


Assuntos
Animais , Bovinos , Resinas Compostas/química , Colagem Dentária/métodos , Esmalte Dentário/química , Corrosão Dentária/métodos , Braquetes Ortodônticos , Resistência ao Cisalhamento , Análise de Variância , Análise do Estresse Dentário , Teste de Materiais , Propriedades de Superfície
15.
Dental press j. orthod. (Impr.) ; 18(2): 18e1-18e5, Mar.-Apr. 2013. ilus, tab
Artigo em Inglês | LILACS | ID: lil-683176

RESUMO

OBJECTIVE: To assess whether palatal mini-implants are effective as direct anchorage for distal movement of the upper molars. METHODS: It was used an acrylic model of the upper dental arch. After making a groove in the region corresponding to dental alveolus, acrylic teeth were fixed in groove with #7 wax, with the roots being previously immersed in adhesive wax. The orthodontic appliance was placed according to the Edgewise technique and then a mini-implant (SIN, São Paulo, Brazil) was inserted at the site corresponding to the palatal raphe. A 0.019 x 0.025-in stainless steel archwire was made and attached to the upper arch with elastics. A transpalatal arch bar (0.019 x 0.025in) was mounted and two hooks were soldered to it in order to retain chain elastics (Unitek, Brazil) to be connected to the mini-implant under a force of 1.5 N on each side. The maxillary model was immersed in water 40 times and photographed after each immersion, for observation of dental movements. Analysis of variance (ANOVA) and Tukey's test were employed for analyzing the obtained data. RESULTS: Molars displaced distally 3.1 mm, in average, with distal inclination ranging from 3 to 5 mm. CONCLUSIONS: Molar movements occurred due to distal inclination, with a slight rotation and no extrusive effect.


OBJETIVO: verificar se o mini-implante no palato é eficaz como ancoragem direta para distalização dos molares superiores. MÉTODOS: foi utilizado um modelo em acrílico da arcada superior. Após a confecção da canaleta na região correspondente aos alvéolos dentários, os dentes em acrílico foram fixados com cera #7, montado aparelho ortodôntico com a técnica Edgewise e inserido um mini-implante (SIN, São Paulo) no local correspondente à rafe palatina. Foram colocados arco 0,19" x 0,25" e barra transpalatina, soldados na barra dois ganchos para retenção de dois elásticos em cadeia de dois elos, a uma carga de 150g/f de cada lado (Unitek), que se estenderam dos ganchos até o mini-implante. O modelo da maxila foi mergulhado 40 vezes em banheira e fotografado após cada mergulho para observação da movimentação dentária. Os dados foram analisados pela análise da variânçia (ANOVA) e teste de Tukey. RESULTADOS: os molares deslocaram-se distalmente 3,1mm, em média, com inclinação distal entre 3 e 5mm. CONCLUÕES: a movimentação dos molares ocorreu pela inclinação distal, com leve rotação, mas sem efeito extrusivo.


Assuntos
Implantes Dentários , Dente Molar , Procedimentos de Ancoragem Ortodôntica/instrumentação , Palato Duro , Técnicas de Movimentação Dentária/instrumentação , Análise de Variância , Modelos Dentários , Dentição Permanente , Procedimentos de Ancoragem Ortodôntica/métodos , Técnicas de Movimentação Dentária/métodos
16.
Dental press j. orthod. (Impr.) ; 18(2): 101-107, Mar.-Apr. 2013. ilus, tab
Artigo em Inglês | LILACS | ID: lil-683191

RESUMO

OBJECTIVE: To mechanically evaluate different systems used for incisors retraction. METHODS: Three different methods for incisors retraction using 0.019 x 0.025-in stainless steel wire were evaluated. The samples were divided into three groups: Group A (retraction arch with 7-mm high vertical hooks); Group G3 (elastic chain attached to the miniimplant and to the 3-mm stainless steel hook soldered to the retraction arch); Group G6 (elastic chain attached to the mini-implant and to the 6-mm stainless steel hook soldered to the retraction arch). A dental mannequin was used for evaluation in order to simulate the desired movements when the device was exposed to a heat source. The analysis of variance (ANOVA) and the Tukey test were used (p < 0.05). RESULTS: The results demonstrated that Groups G3 and G6 exhibited less extrusion and less incisor inclination during the retraction phase (p < 0.05). With regard to incisor extrusion, statistically significant differences were observed between Groups A and G3, and between Groups A and G6 (p < 0.05). Regarding incisor inclination, statistically significant differences were observed between the three systems evaluated (p < 0.05). CONCLUSIONS: Arches with 6-mm vertical hooks allow the force to be applied on the center of resistance of the incisors, thus improving mechanical control when compared with the other two systems.


OBJETIVO: avaliar mecanicamente diferentes sistemas utilizados para retração de incisivos. MÉTODOS: três diferentes métodos de retração dos incisivos foram avaliados, utilizando arco ortodôntico de retração confeccionado com fio de aço inoxidável 0,019" x 0,025" de espessura. Os grupos foram divididos em: Grupo A (arco de retração com alças verticais de 7mm de altura), Grupo G3 (elástico em cadeia ligado do mini-implante ao gancho de aço inoxidável com 3mm de altura soldado no arco de retração) e Grupo G6 (elástico em cadeia ligado do mini-implante ao gancho de aço inoxidável com 6mm de altura soldado no arco de retração). Para essa avaliação, adequou-se um manequim odontológico de tal forma que possibilitasse simular os movimentos desejados, quando fosse exposto a uma fonte de calor. Após obtenção das medidas dos movimentos, realizou-se análise estatística. RESULTADOS: os resultados demonstraram que os grupos G3 e G6 propiciaram menor extrusão e menor inclinação palatina dos incisivos na fase de retração (p<0,05). Quanto à extrusão dos incisivos, houve diferença estatisticamente significativa entre os grupos A e G3, e A e G6 (p<0,05). Em relação à inclinação, ocorreu diferença estatisticamente significativa entre os três sistemas avaliados (p<0,05). CONCLUSÃO: arcos com ganchos verticais de 6mm soldados permitem aproximar a linha de ação da força ao centro de resistência dos incisivos, proporcionando melhor controle mecânico, se comparado aos outros dois sistemas.


Assuntos
Humanos , Implantes Dentários , Incisivo/patologia , Má Oclusão/terapia , Maxila/patologia , Fios Ortodônticos , Procedimentos de Ancoragem Ortodôntica/instrumentação , Técnicas de Movimentação Dentária/instrumentação , Análise de Variância , Manequins , Procedimentos de Ancoragem Ortodôntica/métodos , Técnicas de Movimentação Dentária/métodos
17.
Dental press j. orthod. (Impr.) ; 18(1): 45-49, Jan.-Feb. 2013. ilus
Artigo em Inglês | LILACS | ID: lil-674262

RESUMO

INTRODUCTION: Since the beginning of miniscrews as orthodontic anchorage, many applications have been described in the literature. Among these, one is the uprighting of mesially inclined molars. In regard to the mechanical aspects, however, there is little information about the application of orthodontic forces using such devices. OBJECTIVE: The objective of this study was to describe a miniscrew supported spring for uprighting of mesially inclined molars. With this device, one can achieve the correct use of orthodontic biomechanics, thus favoring more predictable tooth movements and preventing unwanted movements from occurring.


INTRODUÇÃO: desde o surgimento dos mini-implantes como recurso de ancoragem ortodôntica, muitas aplicações têm sido descritas na literatura. Entre essas, cita-se a verticalização de molares inclinados para mesial. No entanto, pouco se fala da correta aplicação das forças ortodônticas nesses dispositivos, sob o ponto de vista mecânico. OBJETIVOS: o objetivo desse artigo foi demonstrar uma mola mini-implante suportada para verticalizar molares inclinados para mesial. Com esse dispositivo consegue-se correta aplicação da mecânica ortodôntica, favorecendo movimentos mais previsíveis e minimizando os movimentos indesejáveis.


Assuntos
Feminino , Humanos , Masculino , Parafusos Ósseos , Dente Molar/anormalidades , Procedimentos de Ancoragem Ortodôntica/instrumentação , Técnicas de Movimentação Dentária/instrumentação , Raiz Dentária/fisiologia , Análise do Estresse Dentário , Técnicas de Movimentação Dentária/métodos , Raiz Dentária
18.
Rev. bras. odontol ; 69(2): 266-271, Jul.-Dez. 2012. ilus, tab
Artigo em Português | LILACS | ID: lil-720356

RESUMO

As ligas de niquel-titânio (Ni-Ti) são usadas na fabricação de fios ortodônticos devido principalmente a sua maior resiliência e menor módulo de elasticidade quando comparadas com outras ligas metálicas, especialmente o aço inoxidável. O objetivo do presente trabalho foi comparar as propriedades mecânicas em flexão de fios de liga com memória de forma de diferentes fabricantes e lotes. Dois lotes de três fabricantes foram ensaiados em flexão três pontos de acordo com a norma ISO 15841:2006(E). Os resultados mostraram que os fios designados como termoativados geram tensões menores que os fios designados como superelásticos, observou-se variações de até 28% entre fios designados como superelásticos e 31% entre fios designados como termoativados. Na comparação dos lotes do mesmo fabricante observou-se também a não homogeneidade entre os fios.


The nickel-titanium (Ni-Ti) alloys are used in the manufacture of orthodontic wires mainly due to its greater resilience and low modulus of elasticity when compared to other alloys, particularly stainless steel. The aim of this study was to compare the mechanical properties of shape memory alloys wires in three-point bending in different manufacturers. Two lots of three manufacturers were tested in three-point bending according to ISO 15841:2006 (E). The results showed that wires designated as termoactivated generated lower tensions than the designated as superelastic, variations of up to 28% between wires designated as superelastic and 31% between wires d esignated as termoactivated were found. In the manufacturer lots comparison was also not observed homogeneity between wires.


Assuntos
Ligas Dentárias , Resistência à Flexão
19.
J. appl. oral sci ; 20(4): 462-466, July-Aug. 2012. ilus, tab
Artigo em Inglês | LILACS | ID: lil-650624

RESUMO

OBJECTIVES: The aim of this study was to assess the optical properties of orthodontic elastic ligatures under the influence of exogenous pigments contained in the daily diet. MATERIAL AND METHODS: For the analysis, colorless (clear) elastic segments (ORTHO Organizers, lot 660625A10) were used as received from the manufacturer, and were divided into 8 groups of 3 segments each. Each group was immersed in 200 mL of a solution containing a determined substance, as follows: distilled water (control group), Coca-Cola®, Pomarola brand tomato sauce (Cica®), açai, Jasmine® brand green tea, Royal Blend® black tea brand, Pilão® brand coffee and Palmares® wine brand. All test specimens were immersed in the solutions and kept in an appropriate receptacle for 7 days at 37°C14. After the staining session, the test specimens were washed with distilled water in an ultrasonic vat for 5 min and dried with paper tissues6. The portable digital spectrophotometer Vita Easyshade Compact was used to assess if there was color variation of the test specimens. This variation was quantified and qualified at the initial time (T0) and after staining (T1). RESULTS: These results were analyzed statistically using the software SPSS version 18.0. The Shapiro-Wilk test of normality was applied followed by the one-way analysis of variance and the Tukey's post hoc test. The level of significance adopted was 5%. CONCLUSIONS: From the substances evaluated in this study, those with higher staining potential on esthetic elastic ligatures were black tea, coffee and wine, respectively. Knowing this information, the dentist may advise their patients to avoid certain foods because of elastic staining may occur thus decreasing the aesthetics of the material.


Assuntos
Humanos , Cor , Materiais Dentários/química , Aparelhos Ortodônticos , Bebidas , Colorimetria , Alimentos , Imersão , Teste de Materiais , Espectrofotometria , Estatísticas não Paramétricas , Propriedades de Superfície , Fatores de Tempo
20.
Dental press j. orthod. (Impr.) ; 17(4): 1-5, July-Aug. 2012. ilus, tab
Artigo em Inglês | LILACS | ID: lil-653498

RESUMO

OBJECTIVES: The objective of the authors was to evaluate fluoride release of 3 glass ionomer cements with immediate protection of fluoride varnish (Cavitine, SS White), divided into 3 groups: Group M (Meron, VOCO), Group V (Vidrion C, SS White) and Group KC (Ketac-Cem, 3M ESPE). METHODS: Fluoride release was measured during 60 days by means of an ion-selective electrode connected to an ion analyzer. After 4 weeks, the test specimens were exposed to a solution of 0.221% sodium fluoride (1000 ppm of fluoride). RESULTS: Results showed that the cements reached a maximum peak of fluoride release in a period of 24 h. There was a statistically significant difference between the amount of fluoride released after the applications of fluoride among the groups from the 31st to 60th day (p> 0.05). CONCLUSION: The Vidrion C and Meron cements showed better performance to uptake and release fluoride when compared with Ketac-Cem cement.


OBJETIVO: o objetivo desse estudo foi avaliar a liberação de flúor dos seguintes três cimentos de ionômero de vidro, com proteção imediata de verniz fluoretado (Cavitine, S. S. White): Meron / VOCO (Grupo M); Vidrion C / S. S. White (Grupo V); e Ketac Cem / 3M ESPE (Grupo KC). MÉTODOS: a liberação de flúor foi medida durante 60 dias, através de eletrodo íon seletivo conectado a um analisador de íons. Após quatro semanas, os corpos de prova foram expostos a uma solução de fluoreto de sódio a 0,221% (1.000ppm de flúor). RESULTADOS: os resultados evidenciaram que os cimentos atingiram o pico máximo de liberação de flúor com 24h após a presa inicial. Houve diferença estatisticamente significativa entre os grupos, quanto à quantidade de flúor liberado após as aplicações de flúor, do 31º ao 60° dia (p > 0,05). CONCLUSÃO: os cimentos Meron e Vidrion apresentaram maior capacidade de captação e liberação de flúor, em comparação ao cimento Ketac Cem.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA